In a manual-clean magnet, captured tramp iron accumulates directly on the magnet face. Capture strength is high because the iron sits at zero air gap, but the accumulation creates three operating problems: the iron layer grows until it shields the field from the burden below, large pieces can be re-entrained into the material stream when the layer thickens, and removal requires stopping or closely attending to the conveyor.
Adding a discharge belt inserts a controlled, thin air gap — typically 15–25 mm between the magnet face and the belt's inner surface. Iron is still pulled through that gap and pins against the belt's outer surface. The belt moves continuously, so the iron is dragged out of the field's edge zone where its hold weakens, then falls into a discharge chute. The physics mirrors what makes a dedicated magnetic roller work: steady transport through a defined field boundary instead of uncontrolled accumulation.
Three engineering consequences follow, and every retrofit decision must account for them:
1. Capture force drops slightly. The 15–25 mm belt gap reduces effective face field strength by roughly 8–15% compared with bare-face contact. A healthy magnet circuit absorbs this; a weak one does not.
2. The burden-to-magnet distance grows. The kit's pulley diameter and belt section add height, so suspension height must usually be raised 30–80 mm, further reducing field strength at the burden surface. The suspension frame and chain hoist need adjustment range.
3. Iron must travel far enough. The belt must carry iron past the field edge and drop it clear of the conveyor's moving material path — or the magnet will simply recycle the same piece of iron forever, the most common field failure after a poorly planned retrofit.![]()
Customer type: Iron ore open-pit mine, 3-shift operation.
Ore type: Iron ore, high drilling-steel and bucket-tooth contamination.
Operating conditions: 1,600 mm belt at 2.2 m/s, 2,800 t/h, three suspended manual-clean permanent magnets (one per conveyor) aged 9–14 years.
Problem: Each shift lost roughly 2 hours to manual cleaning; the conveyor stopped 4–5 times weekly for iron removal; one primary gyratory suffered two liner-damage events in a year traced to elongated steel released by overloaded magnet faces; pull tests showed 6–11% field fade — inside the retrofit window.
Solution: Factory-engineered retrofit kits on all three magnets: face re-machining on the oldest unit, 1.1 kW gearmotor drives, side discharge chutes feeding shared bins, suspension height re-optimized with new chain hoists. Installation completed over two planned weekend shutdowns, with commissioning capture tests at five belt positions per magnet.
Result: Captured-iron weight per day rose about 2.4× as accumulated-layer shielding disappeared; cleaning labor of roughly 5,900 h/yr across the fleet dropped to near zero; cleaning stoppages fell from ~230 h/yr to zero; crusher damage events went from two per year to zero over the following 12 months; total investment ≈ USD 31,000 for three units against ≈ USD 85,000/yr measured benefit — payback in about 4.4 months, with the oldest magnet scheduled for circuit replacement at the next major overhaul as its fade trended toward the 15% limit.![]()
Contact:serena.meng2022@gmail.com
We warmly welcome customers from around the world to contact us and establish mutually beneficial partnerships.
Contactpersoon: Mr. Maple
Tel.: +86 17778255675
Fax: 86--311-80690567